Guide · 02

Designing a unit load from the carton up

Most of a unit load's strength comes from the part people think of as wrapping. Design the pallet, the carton and the film separately and you will reliably overbuild one of them and break another.

The pallet, the product and the packaging are one structure

Send us the carton, not the pallet size

Dimensions, cases per layer, weight, how it is stored and for how long. About a third of the time we come back with a footprint change that costs less and fixes a damage problem the customer had stopped noticing.

Strength in corner columns
60–70%
Real-world carton derating
4–6×
Cost of 1" overhang
up to ~20%
Design order
Carton first, always
A working business address — we reply here, and only here.
US or Canada only. Area code + 7 digits — we format it as you type.
US ZIP (78728 or 78728-1234) or Canadian postal code (M5V 2T6). It must match the state.
Whole units, 1 to 1,000,000. Use the message field for anything approximate.

Fields marked * are required, and we check them properly — a bad phone number or a ZIP that does not match the state will come back to you. Read our privacy notice.

A warehouse floor filled with stacks of recycled pallets, some banded and wrapped, on a polished concrete slab.
Graded stock, under coverStanding-order accounts keep roughly two weeks of cover on the ground here.

Nobody designs a unit load. They specify a pallet, buy a carton, set a wrap programme in 2014, and hope the three get along.

Step one: the carton decides everything

The sequence almost every operation uses is backwards. Procurement standardises on 48×40 because everybody does, the carton is designed to the product, and then the two are introduced to each other on a dock. The correct order is the reverse: the carton's footprint determines the tie pattern, the tie pattern determines the pallet footprint, and only then does the pallet get specified.

This matters because the alternative to designing it is overhang, and overhang is not a cosmetic problem. A carton carries its vertical load almost entirely in its corner columns. Push it an inch out past the pallet edge and the outermost corner bears on nothing — the base panel has to cantilever, and the column that was carrying a large share of the stack above it leaves the load path entirely.

Step two: flush, or very slightly under

1" overhangFlush½" underhang per side
Corner supportLost at the edgeFullFull
Stack strengthMaterially reducedDesign valueDesign value
Cube efficiencyBest on paperGoodMarginally worse
Wrap behaviourFilm cuts into the cornerCleanClean
Handling damageEdges catch racking and other loadsNormalLowest
VerdictAvoidIdealOften the best buy

Half an inch of underhang per side costs a trivial amount of cube and buys clean corners, undamaged edges and film that sits properly. Given a choice between an inch over and an inch under, take under every time.

Step three: the deck gap against the carton

A carton sitting squarely over a deck board is supported along its whole base. A carton sitting over a gap is supported only at its edges and the base panel has to bridge the span — which corrugated board is poor at, and which is why the bottom layer is where crushing starts.

What usually saves a load is bridging: cartons are stiff and interlocked enough that a layer behaves partly like a plate rather than a row of independent boxes. Bridging is genuinely helpful and it also conceals a badly matched pallet, right up to the point where a slightly weaker carton or a slightly wider gap arrives. Measure your carton's short dimension against the deck gap and put the number in the specification. No grade name implies it.

Step four: pick a stacking geometry on purpose

01

Columnar — corners over corners

Dramatically stronger in compression, because 60 to 70 percent of a load's vertical strength lives in the corner columns and this geometry keeps them stacked. Less stable against shear: a hard brake can shift it.

Strong
02

Interlocked — rotated layers

More stable against shear because layers tie together, and meaningfully weaker in compression because the columns no longer line up. The right choice when toppling rather than crushing is your risk.

Stable
03

Hybrid

Columnar through the body of the load with one interlocked layer near the top to tie it together. More work to specify, and usually the best of both for tall loads.

Both

Step five: derate the carton, honestly

The box compression test figure your supplier quotes is a new carton, in a 73 °F and 50% relative humidity laboratory, crushed in seconds. Three things then happen in the real world and they multiply rather than add: time under load costs 40 to 50 percent at ninety days, humidity costs 35 to 50 percent at 85% RH, and handling damage costs another 10 to 25 percent. Applied together, a real safety factor of four to six against the laboratory number is normal.

Step six: specify the pallet dimensionally

By this point you know what the pallet has to do, which means you can specify it properly rather than by grade name. Five numbers: maximum deck gap, minimum entry height, squareness tolerance, minimum board thickness, moisture ceiling. Grade describes a pallet's repair history; these five describe whether it will work.

Step seven: set the wrap by containment force

Film is the cheapest structural element in a unit load and the most often misapplied. The measurement that matters is containment force — the actual pressure the film applies, measured with a plate and gauge at three heights — not wrap count or film gauge, which only describe what you paid for.

  • The profile should not be flat. High containment at the base, moderate through the body, light at the top.
  • Excessive tension at the top pulls the outer columns inward off their corners, which produces crushing at the bottom — a very common self-inflicted failure.
  • Lock the film to the pallet. Two to three revolutions at the base engaging the deck edge, roped or cabled on heavy loads, finishing with a downward pass rather than a tail at the top.
  • A load wrapped beautifully but finishing an inch above the deck will walk off its pallet on the first hard brake.
  • Raise pre-stretch as high as the film tolerates. Thinner film at correct containment force routinely outperforms thick film applied loosely.

Step eight: test the actual thing

Build the load exactly as it ships. Store it exactly as it is stored, for as long as it is stored, in the actual humidity. Then open the bottom layer and look. Every unit load problem we have ever been asked about was visible in that test and invisible in a specification review.

A carton's strength is in its corners. Everything the pallet and the wrap do to the corners, they do to the whole load.


Dimensional appendix

Everything numeric, collected. If you only bookmark one part of this site, make it this.

Footprints

FootprintInchesMillimetresConstructionWhere it livesOur stockPer 53' van
GMA 48×4048" × 40"1219 × 1016Stringer & blockGrocery, general distribution, retailDeep480–560
48×4848" × 48"1219 × 1219StringerDrums, reels, wire, square loadsGood392–420
48×4548" × 45"1219 × 1143StringerAutomotive, tyreGood420–450
48×4248" × 42"1219 × 1067StringerTelecom, paint, coatingsGood440–480
42×4242" × 42"1067 × 1067StringerChemicals, drums, paintGood480–520
40×4840" × 48"1016 × 1219StringerBeverage, rotated GMAGood480–560
40×4040" × 40"1016 × 1016StringerDairy, beverage, bakeryGood520–580
36×3636" × 36"914 × 914StringerCompact, display, light goodsGood640–700
32×3032" × 30"813 × 762StringerRetail display, in-storeLimited900+
30×3030" × 30"762 × 762StringerLight goods, displayLimited960+
48×20 half48" × 20"1219 × 508StringerRetail half pallet, promotionsLimited1,000+
EPAL 147.24" × 31.50"1200 × 800Block, 9 blocksEuropean trade, retailTo order540–600
EPAL 2 / ISO47.24" × 39.37"1200 × 1000BlockEurope, Asia, best container fitTo order480–520
Asia square43.30" × 43.30"1100 × 1100BlockJapan, east AsiaTo order460–500
AU square44.88" × 44.88"1140 × 1140BlockAustralia, chemical CP seriesTo order440–480

Trailer counts are for stacked, unstrapped loads of sound recycled stock and vary with repair thickness. We confirm the actual count on the bill of lading rather than estimating it. Anything not on this list we cut from reclaim — see custom milling.

Container and trailer fit

EquipmentInternal widthInternal length1200×1000 per floor1200×800 per floor48"×40" per floor
20' standard container≈2,352 mm≈5,898 mm101110
40' standard container≈2,352 mm≈12,032 mm20–2123–2420–21
40' high cube container≈2,352 mm≈12,032 mm20–2123–2420–21
45' high cube container≈2,352 mm≈13,556 mm23–2426–2723–24
53' domestic dry van≈2,591 mm≈16,154 mm263026
48' dry van≈2,591 mm≈14,630 mm242724

Floor positions only; stacking depends on product height and weight. The fundamental tension in global freight is in this table: a 40-foot container's internal width does not comfortably take two 48-inch pallets, because the container and the American pallet were standardised in different traditions and never reconciled.

Load ratings

ConstructionStaticDynamicRacked (unsupported)Unit weight
Recycled GMA 48×40 stringer, sound4,600 lb2,800 lb1,500 lb33–45 lb
Recycled 48×40 block, sound5,200 lb3,000 lb1,900 lb40–55 lb
Recycled 48×40 stringer, repaired (B)4,400 lb2,650 lb1,400 lb35–48 lb
New southern yellow pine, 5 top boards4,200 lb2,500 lb1,400 lb33–38 lb
New mixed hardwood block, 7 top boards6,000 lb3,500 lb2,400 lb48–58 lb
Heavy-duty new build, doubled stringers9,000 lb5,000 lb3,800 lb62–78 lb
Skid (no bottom deck)3,800 lb2,200 lbNot for racking24–32 lb

Representative planning figures for sound stock, not engineering certifications. Racked ratings assume the load spans two rails with nothing under the middle. Derate a further 20–30% for dwell times beyond a few weeks, because wood creeps under sustained load.

  • Design ceiling: deflection of span ÷ 100 — about 0.4 inches across a 40-inch unsupported span.
  • Orientation: rack a stringer pallet across the wrong axis and the deck boards carry the span instead of the stringers. Capacity can halve.
  • Creep: wood deflects progressively under sustained load. A unit measured inside tolerance on day one can exceed it after six months in a rack.
  • Stiffness, not strength, is the limit. Mixed hardwood outperforms southern yellow pine in racking by more than their strength figures suggest, because it is substantially stiffer.
  • Drive-in racking gives a long unsupported span with no support at the leading edge. Derate hard, use block construction, consider full-perimeter bottom boards.

Tolerances

Overall footprint
±¼" is normal in recycled stock. ±⅛" is achievable on new builds and worth paying for only if you run automation.
Squareness
Diagonal difference under ½". Beyond that, racking and ASRS reject it, and stretch wrap tightens on two corners and slackens on the other two.
Deck gap
Typically 3½" between boards. Conveyor lines often need a maximum of 3". Specify the number in inches — it is not implied by a grade.
Entry height
Nominal 3½". A repair with thicker boards can lose ¼" and still look fine, then wedge a powered pallet jack.
Board thickness
Nominal ⅝" may measure 0.60–0.66". Specify a minimum if deck flatness matters to your product.
Protruding fasteners
Zero tolerance. Any nail standing above the deck surface condemns the unit at our bench.
Moisture content
19% is the mould threshold and our standard ceiling. 15% on request for food contact and chilled service.
Bark
Some export destinations require debarked wood. Ask before you load, not after.

Grades

Grade AGrade B#1 premium#2 economyCustom cut
Original boardsAllSome replacedAllSeveral replacedMixed
Companion boardsNonePermittedNonePermittedPermitted
Stringer plugsNonePermittedNonePermittedPermitted
Metal platesNonePermitted, disclosedNonePermittedPermitted
SquarenessWithin ¼"Within ½"Within ¼"Within ½"Within ½"
Colour uniformityHighMixedHighMixedMixed, fresh saw ends
Protruding fastenersZeroZeroZeroZeroZero
Moisture ceiling19% (15% on request)19%19% (15% on request)19%19%
Typical serviceRetail-facing, exportInternal, bulkAutomation, rackingOne-way, yard storageOdd footprints
Relative priceHighest recycled−18 to −30%HighLowest≈⅓ of a new build
Remaining lifeLongestShorter — already repaired onceLongestShortestVaries

Grade A and #1 overlap: we use #1 for units that needed no repair at all and A for units that are cosmetically uniform. Where a customer holds their own written standard, that document governs and supersedes these names.

Moisture and equilibrium

Moisture contentWhat happensTypical sourceFreight weight
6–12%Indoor equilibrium. No mould risk. Dimensionally stable.Kiln dried, stored insideLightest
12–19%Safe working range — our standard ceiling.Covered dry stackNormal
19–25%Mould within days to weeks in warm conditions.Rain-exposed stacks, green lumber+5–10%
25–40%Mould rapid, blue stain likely.Pallets left in the open through a wet week+10–20%
Above 40%Saturated. You are paying freight on water.Standing water, flooded yard+20%+

Mould needs free water. Below roughly 19% the water in wood is chemically bound in the cell walls and spores cannot germinate; above it, they can. Heat treatment kills insects and confers no moisture guarantee; kiln drying reduces moisture and is not a phytosanitary treatment. They are separate claims and conflating them causes both mould claims and border holds.

Air temperatureRelative humidityEquilibrium moisture contentDew point — a pallet colder than this will sweat
68 °F30%≈6%≈36 °F
68 °F40%≈7.7%≈43 °F
68 °F55%≈10.2%≈51 °F
68 °F70%≈13.1%≈58 °F
68 °F85%≈18.5%≈64 °F
55 °F60%≈11.3%≈41 °F
75 °F65%≈12.4%≈62 °F

Approximate, for planning. Two separate lessons: wood will eventually equilibrate to whatever air it sits in, and any pallet colder than the dew point of your building's air will condense water on itself and then on your cartons. Acclimatise cold stock indoors for four to twelve hours before loading.

Conversions

InchesmmMillimetresInchesOther
20"508600 mm23.62"1 board foot = 144 in³
24"610800 mm31.50"1 cu yd = 27 cu ft
30"7621,000 mm39.37"1 short ton = 2,000 lb
32"8131,100 mm43.30"1 kg = 2.205 lb
36"9141,140 mm44.88"1" = 25.4 mm exactly
40"1,0161,200 mm47.24"56 °C = 132.8 °F
42"1,0671,219 mm48.00"19% MC = mould threshold
44"1,1181,016 mm40.00"32 bf ≈ one GMA unit
45"1,143914 mm36.00"L/100 = deflection ceiling
48"1,219762 mm30.00"≈500 units per 53' van

Standards, testing and defects

What governs this trade, how pallets are actually tested, and the defect list our benches work from. Published because a specification you can check is worth more to us than a lead we captured.

The documents that govern wood packaging

DocumentIssued byWhat it governsDoes it bind us?
ISPM-15IPPC / FAOPhytosanitary treatment and marking of solid wood packaging crossing bordersYes — we are a registered treating facility
ISO 6780ISOThe six recognised pallet footprints for international tradeReference; we stock four of the six
ISO 8611-1/2/3ISOTest methods, performance requirements and maximum working loads for flat palletsMethods we quote; we do not issue certifications for recycled stock
ISO 18613ISORepair of flat wooden palletsOur bench practice aligns with it
ASTM D1185ASTMStandard test methods for pallets and related structuresReference for new-build testing
ASTM D6179ASTMRough handling of unitised loads — incline impact, drop, vibrationReference for unit-load advice
MIL-STD-1660US DoDDesign criteria for ammunition unit loadsOnly on defence-adjacent work, by request
GMA specificationGrocery Manufacturers Association (historic)The 48×40 footprint, board count and notch geometryThe de facto North American default
NWPCA uniform standardNational Wooden Pallet & Container AssociationRecycled pallet grading vocabularyYes, unless a customer standard supersedes it
EPAL technical regulationsEuropean Pallet AssociationLicensed manufacture and repair of EUR/EPAL palletsNo — we hold no EPAL licence and say so
NHLA rulesNational Hardwood Lumber AssociationHardwood lumber gradingUpstream of us; pallet stock sits below the appearance grades
ANSI MH1ANSI / MHIPallets, slip sheets and other material handling definitionsTerminology reference

We list what does not bind us as deliberately as what does. A supplier vague about which standards it actually holds is the main avoidable risk in this trade.

Test methods and what each one tells you

TestWhat it simulatesWhat it tells youWhere it matters
Compression, edge-supportedRacking across two railsRacked working load and deflectionThe binding constraint in most warehouses
Compression, floor-supportedA load sitting on a flat floorStatic capacity — the biggest and least useful figureFloor storage only
Bending, fork-supportedLifting on forksDynamic capacityEvery movement
Incline impact (conbur)Railcar coupling and hard brakingWhether the unit load stays togetherRail and long-haul road freight
Vibration, random and fixed-frequencyHours of road or rail travelFastener loosening and load settlementLong lanes; this is what kills smooth-shank nails
Drop and corner dropDock mishandlingLead board and corner survivabilityHigh-touch distribution
Fastener withdrawalJoint failure under cyclingService life more than anything else doesEvery pallet, every time
Creep / sustained loadMonths in a rackLong-term deflection; derate 20–30%Slow-moving stock, bagged goods
Moisture determinationStorage realityMould risk and freight weightAll food, chilled and humid-climate work

We publish tested figures for new builds and representative figures for recycled stock. Every unit of reclaim has an individual history, so an engineering certification on recycled wood would imply a precision nobody can hold.

Defects, severity and what we do about each

DefectWhere it showsSeverityWhat our bench does
Lead board split lengthwiseOutermost top board, either endLowBoard swap. Commonest repair in the trade; usually means a steep dock leveller
Interior deck board crackAny top or bottom boardLowBoard swap, or companion board where removal would damage the stringer
End-grain separationBoard end, at the nail lineTerminal for that boardBoard removed and harvested short, or ground. It predicts the next failure
Stringer crack, not crossing a notchOuter or centre stringerMediumPlug if over a third of the depth; otherwise re-nail and pass
Stringer crack crossing a notchAt a notch cornerHighPlug or condemn. The load path through that stringer is gone
Protruding fastenerAnywhere on the deckZero toleranceDriven or replaced before the unit leaves, no exceptions
Loose joint / creakWhole unitMediumFull re-nail. A creaking pallet has already failed at the joints
Missing chamferBottom board lead edgeMediumRe-chamfer. Without it every pallet jack fights the unit
Out of square beyond ½"DiagonalsMedium–highCorrected or condemned. Racking, ASRS and stretch wrap all reject it
Moisture above 19%Whole unitHighDry stack or kiln before repair. Mould is then a question of time
Blue stain / sapstainSapwood facesCosmetic, plus odourRejected for food and absorbent product; fine elsewhere
Bark / waneBoard edgesLow, unless exportRemoved where a destination requires debarked wood
Mould, visibleAny surfaceRejectNever shipped to a food account; dried and re-graded or ground
Paint, stain, coatingAny surfaceRejectSegregated at the gate; industrial fuel stream only
Oil or chemical contaminationAny surfaceRefusedRefused at the gate and the customer is told why
Embedded metal beyond fastenersAnywhereHighRemoved by hand before any grind; it destroys knives

Fastener specifications

FastenerTypical lengthWire gaugeMIBANT bend angleUsed in
Helical, hardened2¼"–2½"0.099–0.120"10–20°Stringers and blocks, hardwood
Helical, standard2"–2¼"0.099–0.113"20–30°Stringers in softwood
Ring shank, hardened1¾"–2¼"0.099–0.113"15–25°Deck boards, repairs
Ring shank, standard1½"–2"0.092–0.105"25–35°Deck boards, lighter stock
Ring shank, galvanised1¾"–2¼"0.099–0.113"20–30°Outdoor and wash-down service
Staple, crown1¼"–1¾"16–15 gaugen/aCollar panels, crate sheathing, lids
Smooth shankanyanyanyNothing we build

A lower MIBANT angle means harder, more brittle steel — better withdrawal, more prone to shearing on impact. A higher angle means softer steel that bends rather than snapping, and joints that loosen. Pallet builders pick a window; cheap builders pick a price. 60 to 78 fasteners go into a standard GMA unit.

Export appendix

Destination notes, loading patterns and the bracing rule that removes the commonest border hold there is.

Destination notes

Destination regionISPM-15Notable additional measuresPractical advice
European Union / UKRequiredDebarked wood required; strict on dunnageDebark, treat, mark two sides, and audit your bracing
ChinaRequiredDocumentation scrutiny; MB increasingly unwelcomeHeat treatment only; keep the chart trace in the file
Australia / New ZealandRequiredAmong the strictest inspection regimes anywhereExpect inspection; immaculate marks and no bark
Canada / MexicoRequired between NAFTA-region states for most woodLand crossings inspect quickly and unsentimentallyTreat and mark everything, including the skid under an awkward item
Brazil / MercosurRequiredMarking legibility enforcedTwo opposite sides, nothing obscured by labels
Japan / South KoreaRequiredFumigation records examined closelyHeat treatment removes the question
Middle East / GulfRequiredVariable national measuresCheck per country before loading, not after
IndiaRequiredAdditional declarations in some statesConfirm with your forwarder in advance
Within the United StatesNot required—Treatment only matters for onward export

Indicative only, and national measures change. Confirm the destination's current requirements with your forwarder before loading — we will review the packaging side of your documentation at no charge if you send it to us.

Trailer loading patterns

PatternHow it loadsPositions in a 53' vanTrade-off
Straight / squarePallets squared to the trailer walls, two across26Simplest, fastest, most stable. The default
Turned (rotated 90°)Pallets turned so the 48" face runs across24–26Fits some footprints better; check racking orientation at the far end
PinwheelAlternating orientation in each row24–26Fills awkward widths; slower to load and harder to brace
Chimney / centre gapDeliberate void down the middle22–24Air movement for produce; loses positions
Double stackTwo tiers where product and height allowup to 52Doubles capacity; needs a cap or a strong top layer
Floor loaded (no pallets)Cases hand-stackedn/aMaximum cube, maximum labour, and the reason pallets were invented

Positions assume 48×40 units. Bracing matters more than pattern: void fillers and marked, treated bracing timber prevent the shifting that incline-impact testing is designed to simulate.

Dunnage and bracing

Void fill
Airbags, honeycomb panels or marked bracing timber. Any solid wood used is regulated under ISPM-15 exactly like the pallet.
Bracing timber
Keep a bundle of pre-treated, IPPC-marked 2×4 at the dock and make it the only wood permitted into a container. This single rule removes the commonest border hold there is.
Load bars and straps
Not regulated, and not a substitute for bracing on a shifting load.
Corner boards
Reclaimed block stock protects strapped corners and adds vertical crush strength. Cheap, and routinely omitted.
Slip sheets
Not solid wood, so outside ISPM-15 entirely — a real advantage on export lanes, offset by needing a push-pull attachment at both ends.
Top caps
Rigid hardwood caps distribute a stacked load across collar walls rather than into the product below.
Loading checklist line
“All solid wood in this container is ISPM-15 marked”, signed by the loader. One line, and it changes behaviour.
Get a quoteFull form · no phone needed